{"HAPI": "3.0", "status": {"code": 1200, "message": "OK"}, "x_dataset": "GF2_OPER_FGM_ACAL_CORR", "x_datasetType": "GFx_FGM_ACAL", "startDate": "2018-06-01T00:00:00Z", "stopDate": "2026-02-28T23:59:59Z", "cadence": "PT1S", "x_maxTimeSelection": "P5D", "modificationDate": "2026-03-26T03:48:53.805Z", "description": "GRACE-FO 2 platform magnetometer measurements", "x_dataTerms": "This dataset is provided by the European Space Agency and it is subject to terms condition described in https://vires.services/data_terms.", "resourceURL": "https://doi.org/10.1186/s40623-021-01364-w", "citation": "https://doi.org/10.5880/GFZ.2.3.2021.002", "parameters": [{"name": "Timestamp", "description": "Time stamp", "units": "UTC", "type": "isotime", "length": 24, "x_standard": "UTC", "x_epoch": "1970-01-01T00:00:00Z", "x_unit": "ms", "x_type": "int64", "fill": null}, {"name": "Latitude", "description": "Position in ITRF - Latitude", "units": "deg", "type": "double", "x_type": "float64", "fill": null}, {"name": "Longitude", "description": "Position in ITRF - Longitude", "units": "deg", "type": "double", "x_type": "float64", "fill": null}, {"name": "Radius", "description": "Position in ITRF - Radius", "units": "m", "type": "double", "x_type": "float64", "fill": null}, {"name": "B_FGM", "size": [3], "description": "Fluxgate magnetometer, FGM, aligned, vector-vector calibrated and corrected for satellite disturbances, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "B_NEC", "size": [3], "description": "Fluxgate magnetometer, FGM, aligned, vector-vector calibrated and corrected for satellite disturbances, NEC frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "q_NEC_FGM", "size": [4], "description": "Quaternion, transformation: NEC ... FGM", "units": null, "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_MTQ_FGM", "size": [3], "description": "Disturbance field related to magnetorquer, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_XI_FGM", "size": [3], "description": "Disturbance field related to 2nd order non-linearities, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_NY_FGM", "size": [3], "description": "Disturbance field related to 3rd order non-linearities, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_BT_FGM", "size": [3], "description": "Disturbance field related to temperature dependency of offsets, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_ST_FGM", "size": [3], "description": "Disturbance field related to temperature dependency of scale factors, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_SA_FGM", "size": [3], "description": "Disturbance field related to solar array currents, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "dB_BAT_FGM", "size": [3], "description": "Disturbance field related to battery currents, FGM frame", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "B_FLAG", "description": "Flags", "units": null, "type": "integer", "x_type": "uint8", "fill": null}, {"name": "F", "description": "Magnetic field intensity calculated from B_NEC", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "B_NEC_Model", "size": [3], "description": "CHAOS magnetic model", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "F_Model", "description": "CHAOS magnetic model, field intensity", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "F_res_Model", "description": "Magnetic field intensity calculated from B_NEC, CHAOS magnetic model residual", "units": "nT", "type": "double", "x_type": "float64", "fill": null}, {"name": "B_NEC_res_Model", "size": [3], "description": "Fluxgate magnetometer, FGM, aligned, vector-vector calibrated and corrected for satellite disturbances, NEC frame, CHAOS magnetic model residual", "units": "nT", "type": "double", "x_type": "float64", "fill": null}]}